User Tools

Site Tools


storage:brocade_monitoring

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
storage:brocade_monitoring [2022/02/12 19:53]
manu
storage:brocade_monitoring [2025/04/24 17:05] (current)
manu
Line 1: Line 1:
 ====== Brocade monitoring ====== ====== Brocade monitoring ======
 +
 +===== SAN switch health =====
 +
 +<cli prompt='>'>​
 +switch:​admin>​ mapsdb --show
 + 
 +1 Dashboard Information:​
 +=======================
 + 
 +DB start time:                  Mon Sep 23 16:54:43 2024
 +Active policy: ​                 dflt_aggressive_policy
 +Configured Notifications: ​      ​RASLOG,​SW_CRITICAL,​SW_MARGINAL,​SFP_MARGINAL,​FPIN,​HA_RECOVER
 +Fenced Ports :                  None
 +Decommissioned Ports :          None
 +Fenced circuits :               N/A
 +Quarantined Ports :             None
 +Top Zoned PIDs <​pid(it-flows)>:​
 + 
 +2 Switch Health Report:
 +=======================
 + 
 +Current Switch Policy Status: HEALTHY
 + 
 + 
 +3.1 Summary Report:
 +===================
 + 
 +Category ​                ​|Today ​                    |Last 7 days               |
 +--------------------------------------------------------------------------------
 +Port Health ​             |No Errors ​                |No Errors ​                |
 +Fru Health ​              |In operating range        |In operating range        |
 +Security Violations ​     |No Errors ​                |No Errors ​                |
 +Fabric State Changes ​    |No Errors ​                |No Errors ​                |
 +Switch Resource ​         |Out of operating range    |In operating range        |
 +Fabric Performance Impact|In operating range        |In operating range        |
 +IO Health ​               |In operating range        |In operating range        |
 +IO Latency ​              |In operating range        |In operating range        |
 + 
 + 
 +3.2 Rules Affecting Health:
 +===========================
 + 
 +Category(Violation Count)|RepeatCount|Rule Name      |Execution Time   ​|Object ​    ​|Triggered Value(Units)|
 +-----------------------------------------------------------------------------------------------------------
 +Switch Resource(1) ​      ​|1 ​         |defALL_TSTEMP_ |09/23/24 16:​57:​00|Temperature|OUT_OF_RANGE ​         |             ​| ​          ​| ​  ​OUT_OF_RANGE| ​               |   ​Sensor 2|
 +</​cli>​
  
 ===== Nagios plugins ===== ===== Nagios plugins =====
 +
 +RestAPI tools \\
 +https://​github.com/​jconsoli
  
 https://​github.com/​ovido/​nagios-plugins/​blob/​master/​check_snmp_brocade https://​github.com/​ovido/​nagios-plugins/​blob/​master/​check_snmp_brocade
storage/brocade_monitoring.1644692001.txt.gz ยท Last modified: 2022/02/12 19:53 by manu