 +===== SVC Enhanced Stretch Cluster ======
 +
 +For stretched systems that use the enhanced configuration functions, **storage systems that are configured to one of the main sites (1 or 2) need be zoned only to be visible by the nodes in that site**. Storage systems in site 3 or storage systems that have no site that is defined must be zoned to all nodes.
 +
 +Note: ISLs must not be shared between private and public virtual fabrics.
 +
 +Configure Enhanced Stretch Cluster
 +
 +https://​www.ibm.com/​docs/​en/​spectrumvirtualsoftw/​8.2.x?​topic=details-configuring-enhanced-stretched-system
 +
 +===== Speed for mirroring =====
  
 For information,​ for volume mirroring, the max speed is sync rate 100% corresponding to 64MB/s For information,​ for volume mirroring, the max speed is sync rate 100% corresponding to 64MB/s
 +
 +==== SAN switches ====
 +
 +**buffer credit on SAN switches**
 +  40 for 16Gb or 32Gb
 +
 +
 +**workload segregation**
 +  on storage dedicated ports for high speed traffic ex: 32Gb
 +  and other ports for lower speed 8Gb / 16Gb using zoning
 +
  
 ==== FCM optimization ==== ==== FCM optimization ====
Line 85: Line 108:
  
 When using **compression on storage**, reduce block size on host to a value lower than **64k** When using **compression on storage**, reduce block size on host to a value lower than **64k**
 +
 +FIXME v8.4 and higher: Where possible limit the maximum transfer size sent to the IBM FlashSystem to 
 +no more than **256 KiB**. This limitation is general best practice and not specific to only 
  
 **Details**\\ **Details**\\
Line 127: Line 153:
  
 ==== Linux optimization ==== ==== Linux optimization ====
 +
 +FIXME v8.4 and higher: Where possible limit the maximum transfer size sent to the IBM FlashSystem to 
 +no more than **256 KiB**. This limitation is general best practice and not specific to only 
  
 Using compression on SVC volumes, the best is to set IO size to 64k Using compression on SVC volumes, the best is to set IO size to 64k
Line 145: Line 174:
 </​cli>​ </​cli>​
  
 +Use the command : **udevadm info -a**
 ===== Perf issue on SAN / Storage ===== ===== Perf issue on SAN / Storage =====
  
Line 156: Line 186:
 <cli prompt='>'>​ <cli prompt='>'>​
 IBM_FlashSystem:​V5100-02:​superuser>​lsvdiskcopy | grep del IBM_FlashSystem:​V5100-02:​superuser>​lsvdiskcopy | grep del
-125      l0000-DB01 ​          ​0       ​deleting yes  no      0            Pool0          200.00GB striped no      on        balanced ​        ​yes ​            ​0 ​                  ​Pool0 ​                ​no ​     yes+125      l0000-DB01 ​       0       ​deleting yes  no      0            Pool0          200.00GB striped no      on        balanced ​        ​yes ​            ​0 ​                  ​Pool0 ​                ​no ​     yes
 148      l0000-tap04 ​      ​0 ​      ​deleting yes  no      0            Pool0          200.00GB striped no      on        balanced ​        ​yes ​            ​0 ​                  ​Pool0 ​                ​no ​     yes 148      l0000-tap04 ​      ​0 ​      ​deleting yes  no      0            Pool0          200.00GB striped no      on        balanced ​        ​yes ​            ​0 ​                  ​Pool0 ​                ​no ​     yes
 149      l0000-tap03 ​      ​0 ​      ​deleting yes  no      0            Pool0          200.00GB striped no      on        balanced ​        ​yes ​            ​0 ​                  ​Pool0 ​                ​no ​     yes 149      l0000-tap03 ​      ​0 ​      ​deleting yes  no      0            Pool0          200.00GB striped no      on        balanced ​        ​yes ​            ​0 ​                  ​Pool0 ​                ​no ​     yes