Line 323: Line 323:
 //Error// using replication metro mirror (PPRC) or global mirror --> change the system layout on all devices to have the same virtualization layer //Error// using replication metro mirror (PPRC) or global mirror --> change the system layout on all devices to have the same virtualization layer
  
-==== Enable SVC NPIV ====+==== Enable SVC NPIV (required in v8.7) ====
  
 Here we talk about SVC FC port virtualization,​ host with NPIV is supported for a long time. Here we talk about SVC FC port virtualization,​ host with NPIV is supported for a long time.
 +
 +=== Change from Not virtualized to Transitional ===
  
 Enabling NPIV target port functionality on a new cluster Enabling NPIV target port functionality on a new cluster
 After creating the cluster, but before starting to add hosts, issue  After creating the cluster, but before starting to add hosts, issue 
-  ​chiogrp fctargetportmode transitional <IO group> ​+<​cli>​ 
 +  ​chiogrp ​-fctargetportmode transitional <IO group>  
 +</cli>
 on each populated I/O group. ​ on each populated I/O group. ​
-Once that is doneissue  + 
-  chiogrp fctargetportmode enabled <IO group+=== Update the zoning for ports connected to hosts === 
 + 
 +    Ensure ​that the hosts are using the NPIV ports for host I/O. To verify that you are logged in to these hosts with these NPIV portsenter the following command 
 +<​cli>​ 
 +lsfabric -host host_id_or_name 
 +</​cli>​ 
 +Wait a minimum of 15 minutes before you move from transitional to enabled state.  
 + 
 +=== Change from Transitional to NPIV === 
 + 
 +To change the NPIV setting to enabled, enter the following command: 
 +<cli> 
 +chiogrp ​-fctargetportmode enabled 
 +</cli> 
 on each populated I/O group. on each populated I/O group.
 If using WWPN based zoning, issue the command to view the set of FC ports. ​ If using WWPN based zoning, issue the command to view the set of FC ports. ​
 +<cli>
   lstargetportfc ​   lstargetportfc ​
 +</​cli>​
 All ports that display virtualized=yes need to be zoned into hosts as described above. All ports that display virtualized=yes need to be zoned into hosts as described above.
  
Line 682: Line 702:
 </​cli>​ </​cli>​
            
 +     
 +===== Replace SVC node ======
 +
 +<cli>
 +satask installsoftware -file IBM_5.0.12 -ignore
 +</​cli>​
 +
 +<cli>
 +sainfo lsservicenode
 +</​cli>​
 +
 +
 +<cli>
 +satask chvpd -wwnn 500507680F00FFFF -fcportmap 11-11,​12-12,​13-13,​14-14,​21-21,​22-22,​23-23,​24-24
 +</​cli>​
 +