storage:svc_esc_config [2024/11/08 00:05]
manu [Storage connectivity]
storage:svc_esc_config [2025/03/17 17:17] (current)
manu
Line 5: Line 5:
 Example of cabling Example of cabling
  
-In the best recommandations,​ alternate one port on Fabric SAN A, then a port on B...+In the best recommandations,​ alternate one port on Fabric SAN A (blue), then a port on B (red)... 
 + 
 +{{:​storage:​svc_fc_connexions_08.png?​4000}} 
 + 
 +{{:​storage:​svc_fc_connexions_09.png?​2000}}
  
-{{:​storage:​SVC SA2-SV3 connection.png?​650}} 
  
 Set the port mask to 11, so only ports 1 and 2 are able to communicate in node Set the port mask to 11, so only ports 1 and 2 are able to communicate in node
 <cli prompt='>'>​ <cli prompt='>'>​
-SVC:​superuser>​chsystem -localfcportmask ​00000011 ​+SVC:​superuser>​chsystem -localfcportmask ​00001100 ​
  
 SVC:​superuser>​lssystem |grep mask SVC:​superuser>​lssystem |grep mask
-local_fc_port_mask ​0000000000000000000000000000000000000000000000000000000000000011+local_fc_port_mask ​00000000000000000000000000000000000000000000000000000000001100
 </​cli>​ </​cli>​
  
-FIXME Why using 2 set of ports for host with different speed ?\\ +FIXME Why using 2 set of ports for host with different speed flagged 16Gb and 32Gb?\\ 
-It's a best practice preventing SVC ports to negotiate between different speeds on hosts+It's a best practice preventing SVC ports to negotiate between different speeds on hosts. Dedicated ports for high speed traffic. But on SAN switches leave the auto-negotiation so both can do 32Gb.
  
 {{:​storage:​SAN zoning for SVC enhanced stretch cluster.png?​650}} {{:​storage:​SAN zoning for SVC enhanced stretch cluster.png?​650}}
storage/svc_esc_config.1731020729.txt.gz · Last modified: 2024/11/08 00:05 by manu