Line 3: Line 3:
 Easier way to upgrade is using GUI to upgrade Easier way to upgrade is using GUI to upgrade
  
-=== Precheck: ===+===== Precheck: ===== 
   * depending on hardware, check the required level available   * depending on hardware, check the required level available
 +<​code>​Ex:​ => google: ​ Hardware Interoperability Matrix v7000 </​code>​
   * check the upgrade steps, maybe you cannot update in one step from 8.1.7 to 8.3.1.3 !   * check the upgrade steps, maybe you cannot update in one step from 8.1.7 to 8.3.1.3 !
 +<​code>​Ex:​ => google: ​ Concurrent Compatibility and Code Cross Reference for Spectrum Virtualize </​code>​
  
 Download the test utility (required) and package upgrade Download the test utility (required) and package upgrade
Line 41: Line 44:
 </​cli>​ </​cli>​
  
-=== On SVC cluster (Spectrum Virtualize) ===+===== On SVC cluster (Spectrum Virtualize) ===== 
 <cli prompt='>'>​ <cli prompt='>'>​
 IBM_2145:​SVC01:​admin>​lsnode IBM_2145:​SVC01:​admin>​lsnode
Line 55: Line 59:
 </​cli>​ </​cli>​
  
-=== check IP quorums ===+===== check IP quorums ​=====
  
 On Hyperswap cluster : v7k... and on SVC, check quorums, specificaly IP (an update is maybe useful) On Hyperswap cluster : v7k... and on SVC, check quorums, specificaly IP (an update is maybe useful)
-  All quorums must be **online** and one IP quorum **active**+  All quorums must be **online** and one IP quorum **active** ​when upgrade is finished
 <cli prompt='>'>​ <cli prompt='>'>​
 IBM_Storwize:​V7K01:​admin>​lsquorum IBM_Storwize:​V7K01:​admin>​lsquorum
Line 104: Line 108:
   ​   ​
 Then wait ... Then wait ...
 +
 +When upgrade starts, follow the progress with (about 4 minutes per drive):
 +<cli prompt='>'>​
 +IBM_Storwize:​V7K01:​admin>​lsdriveupgradeprogress
 +id  status ​       estimated_completion_time
 +12  not_scheduled
 +13  not_scheduled
 +14  not_scheduled
 +15  not_scheduled
 +16  not_scheduled
 +17  not_scheduled
 +18  not_scheduled
 +</​cli>​
 +
 +===== Quorum IP =====
 +
 +Create a service with downloaded file **ip_quorum.jar** from storage SVC or v7000, and open firewall port :**1260**
 +
 +==== On windows: ====
 +
 +<cli prompt='>'>​
 +sc.exe create "​IBM_IP_quorum"​ binPath= "​F:​\<​javapath>​\java -jar ip_quorum.jar"​
 +</​cli>​
 +
 +To delete service:
 +<cli prompt='>'>​
 +sc.exe delete SERVICE NAME
 +</​cli>​
 +
 +==== On Linux: ====
 +
 +