Previous revision
storage:v7k_firmwaredisk [2022/01/15 10:10]
manu
storage:v7k_firmwaredisk [2024/09/10 17:12] (current)
manu [ERRORS]
Line 22: Line 22:
 </​cli>​ </​cli>​
  
 +==== For new versions ====
  
 +<cli prompt='>'>​
 +IBM_FlashSystem:​f7krcs1:​superuser>​svcupgradetest -w  IBM_FlashSystem7x00_and_StorwizeV7000_8.5.0.0_AND_LATER_ALL_DRIVES_230925
 +rbash: svcupgradetest:​ command not found
 +
 +IBM_FlashSystem:​f7krcs1:​superuser>​svctask applysoftware -file IBM_INSTALL_FROM_8.5_AND_LATER_upgradetest_41.1
 +CMMVC9001I The package installed successfully.
 +
 +IBM_FlashSystem:​f7krcs1:​superuser>​svcupgradetest -w  IBM_FlashSystem7x00_and_StorwizeV7000_8.5.0.0_AND_LATER_ALL_DRIVES_230925
 +svcupgradetest version 41.1
 +
 +Please wait, the test may take several minutes to complete.
 +
 +Build version 231005_1440
 +
 +Results of running svcupgradetest:​
 +==================================
 +
 +All drives have passed all the required pre-firmware upgrade checks.
 +Proceed with drive firmware upgrade shortly.
 +
 +IBM_FlashSystem:​f7krcs1:​superuser>​applydrivesoftware -file IBM_FlashSystem7x00_and_StorwizeV7000_8.5.0.0_AND_LATER_ALL_DRIVES_230925 -all
 +
 +IBM_FlashSystem:​f7krcs1:​superuser>​lsdriveupgradeprogress
 +id status ​   estimated_completion_time
 +0  upgrading 231011142128
 +1  scheduled
 +2  scheduled
 +3  scheduled
 +4  scheduled
 +5  scheduled
 +6  scheduled
 +7  scheduled
 +8  scheduled
 +9  scheduled
 +10 scheduled
 +11 scheduled
 +12 scheduled
 +13 scheduled
 +14 scheduled
 +15 scheduled
 +</​cli>​
  
 === Check for firmware on V3700 === === Check for firmware on V3700 ===
Line 119: Line 161:
 Jobs are still pending during days when using command **lsdriveupgradeprogress** Jobs are still pending during days when using command **lsdriveupgradeprogress**
  
-Try to apply the firmware on a not existing disk+**<color #ed1c24>Try to apply the firmware on a not existing disk</​color>​**
 <cli prompt='>'>​ <cli prompt='>'>​
 IBM_Storwize:​V7K:​superuser >​applydrivesoftware -drive 999  -file /​home/​admin/​upgrade/​IBM_FlashSystem7x00_and_StorwizeV7000_SAS_DRIVE_201027 -type firmware IBM_Storwize:​V7K:​superuser >​applydrivesoftware -drive 999  -file /​home/​admin/​upgrade/​IBM_FlashSystem7x00_and_StorwizeV7000_SAS_DRIVE_201027 -type firmware
storage/v7k_firmwaredisk.1642237858.txt.gz · Last modified: 2022/01/15 10:10 by manu