Line 9: Line 9:
   * Mark the drive that requires a reseat as failed (even if this drive is already in '​failed'​ state) via **chdrive -use failed 6** (NOTE: check that there is sufficient redundancy in the array before doing this).   * Mark the drive that requires a reseat as failed (even if this drive is already in '​failed'​ state) via **chdrive -use failed 6** (NOTE: check that there is sufficient redundancy in the array before doing this).
     ​     ​
-    ​Mark the failed drive as unused via the GUI or via **chdrive -use unused 6**. This logically removes the drive from the array and means it will not automatically add back in after being reseated.+  * Mark the failed drive as unused via the GUI or via **chdrive -use unused 6**. This logically removes the drive from the array and means it will not automatically add back in after being reseated.
     ​     ​
-    ​Re-seat the drive, or perform a virtual power cycle of the drive slot by running the command **chenclosureslot -slot 2 -power cycle 1**. Wait until the drive is online (can take up to 5 minutes)+  * Re-seat the drive, or perform a virtual power cycle of the drive slot by running the command **chenclosureslot -slot 2 -power cycle 1**. Wait until the drive is online (can take up to 5 minutes)
     ​     ​
-    ​If the drive comes back as 1674 "Drive offline because it is locked by a missing encryption key", secure erase this drive via GUI or CLI **chdrive -task erase 6**. Wait until the drive is online (can take up to 5 minutes)+  * If the drive comes back as 1674 "Drive offline because it is locked by a missing encryption key", secure erase this drive via GUI or CLI **chdrive -task erase 6**. Wait until the drive is online (can take up to 5 minutes)
     ​     ​
-    ​Trigger at least two drive dump after the power cycle with **triggerdrivedump 6**. This will ensure that older data are de-staged from the FCM internal memory and newer data could follow in the next drivedump.+  * Trigger at least two drive dump after the power cycle with **triggerdrivedump 6**. This will ensure that older data are de-staged from the FCM internal memory and newer data could follow in the next drivedump.
     ​     ​
-    ​Upload a SNAP option 1 (this will also include the drivedump) for IBM support review +  * Upload a SNAP option 1 (this will also include the drivedump) for IBM support reviewWait until we completed the drivedump analysis before integrating the drive back in the array. ​
-    ​Wait until we completed the drivedump analysis before integrating the drive back in the array. ​+
     ​     ​
 ===== Procedure 2 ===== ===== Procedure 2 =====