This is an old revision of the document!
Example of cabling
In the best recommandations, alternate one port on Fabric SAN A, then a port on B…
Set the port mask to 11, so only ports 1 and 2 are able to communicate in node
SVC:superuser>chsystem -localfcportmask 00000011 SVC:superuser>lssystem |grep mask local_fc_port_mask 0000000000000000000000000000000000000000000000000000000000000011
Why using 2 set of ports for host with different speed ?
It's a best practice preventing SVC ports to negotiate between different speeds on hosts
SVC port connexion to SAN SW
https://www.ibm.com/support/pages/troubleshooting-svcstorwize-npiv-connectivity
Nowadays (2024), storage using NVMe are not supported, only SCSI over FC. Hosts are supported with NVMe over FC, SCSI over FC, … network storage protocols
For storage IBM change the layer at storage array to storage
V7000:superuser> chsystem -layer storage
Before configuring all SVC nodes, wait:
Now you are ready to configure the Enhanced Stretch Cluster
You can use either the GUI or the command line
3 sites are available by default (lssite), site 3 can't be set as it's assigned to IPquorum
Now you can check the result
SVC:superuser> lssystem | grep topology