 ====== AIX tuning performance ====== ====== AIX tuning performance ======
  
-===== LPM between ​Pç and P8 =====+===== Network tuning ===== 
 + 
 +https://​www.ibm.com/​support/​pages/​node/​7038687 
 + 
 +https://​www.ibm.com/​support/​pages/​node/​6410510 
 + 
 +For LPARs 
 +<​cli>​ 
 +no -p -o tcp_sendspace=1048576 
 +no -p -o tcp_recvspace=1048576 
 +no -p -o sb_max=2097152 
 +no -p -o rfc1323=1 
 +no -p -o tcp_nodelayack=0 
 +no -p -o sack=1 
 +chdev -l enX -a mtu_bypass=on 
 +no -p -o tcp_init_window=10 
 +no -p -o rfc2414=1 
 +no -p -o tcp_cubic=1 
 +</​cli>​ 
 + 
 +===== VIOS tuning ===== 
 + 
 +http://​capacityreports.com/​VIO/​VIOTuning/​vio_tuning_server.html 
 + 
 +http://​gibsonnet.net/​blog/​dwarchive/​New%20FC%20adapter%20port%20queue%20depth%20tuning%20(Chris%27s%20AIX%20Blog).html 
 + 
 +INFO 
 +  On each parameter that can be changed, you can check available values:  
 +  lsattr -l fcs0 -a max_npivs 
 +   
 +==== disk ==== 
 + 
 +=== queue_depth === 
 + 
 +For the logical drive (which is known as the hdisk in AIX), the setting is the attribute 
 +queue_depth,​ as shown in the following example: 
 +  # chdev -l hdiskX -a queue_depth=Y -P 
 +In this example, X is the hdisk number, and Y is the value to which you are setting X for 
 +queue_depth. 
 + 
 +For a high-volume transaction workload of small random transfers, try a queue_depth value of 
 +25 or more. For large sequential workloads, performance is better with small queue depths, such as a value of 4 
 + 
 +==== FC adapter ==== 
 + 
 +=== max_npivs === 
 + 
 +If you reach limit in NPIV connections on physical VIOS ports, you can increase the maximum 
 + 
 +Change max_npivs 
 +<cli prompt='#'>​ 
 +# chdev -l fcs0 -a max_npivs=128 -P 
 +fcs0 changed 
 +# exit 
 +</​cli>​ 
 +<cli prompt='​$'>​ 
 +$ shutdown -restart 
 +</​cli>​  
 + 
 +After reboot: 
 +<cli prompt='​$'>​ 
 +$ lsnports 
 +name             ​physloc ​                       fabric tports aports swwpns ​ awwpns 
 +fcs0             ​U2C4E.001.DBJ8765-P2-C5-T1 ​         1    128    127   ​2048 ​   2045 
 +fcs1             ​U2C4E.001.DBJ8765-P2-C5-T2 ​         0     ​64 ​    ​64 ​  ​2048 ​   2048 
 +</​cli>​ 
 + 
 +//​adapters://​ 
 +  * 16Gbps or less FC adapters: value=64 
 +  * 32Gbps FC adapters: value=255 
 + 
 +=== max_xfer_size === 
 + 
 +FIXME set first the xfer size on VIOS, which have to be higher or equal than LPAR vFC attribute, else the LPAR would be unable to boot 
 + 
 +With the default value of max_xfer_size=0x100000,​ the area is 16 MB, and for other allowable values of the max_xfer_size attribute, the memory area is 128 MB. 
 + 
 +=== num_cmd_elements === 
 + 
 +Check values, defined and runing 
 +<cli prompt='#'>​ 
 +# chdev -l fcs0 -a num_cmd_elems=1024 -P 
 +fcs0 changed 
 + 
 +# lsattr -El fcs0 -a num_cmd_elems 
 +num_cmd_elems 1024 Maximum Number of COMMAND Elements True       <<​ ODM 
 + 
 +# lsattr -Pl fcs0 -a num_cmd_elems 
 +num_cmd_elems 400 Maximum Number of COMMAND Elements True        << Running 
 +</​cli>​ 
 + 
 +or AIX 7.3 
 +<cli prompt='#'>​ 
 +# grep num_cmd /​proc/​sys/​adapter/​fc/​fcs0/​tunables 
 +num_cmd_elems ​  ( Requested / Granted ):     1024 / 1024 
 +</​cli>​ 
 + 
 +or 
 +<cli prompt='#'>​ 
 +# genkex ​ | grep fscsi 
 +f10009d5a01e5000 ​   f8000 /​usr/​lib/​drivers/​emfscsidd 
 + 
 +# oslevel -s 
 +7200-05-04-2220 
 + 
 +# echo emfscsi -d fscsi0 | kdb -script | grep num_cmd 
 +        int num_cmd_elems = 0x17C      
 + 
 +# printf "​%d\n"​ 0x17C 
 +380 
 + 
 +# lsattr -El fcs0 -a num_cmd_elems 
 +num_cmd_elems 400 Maximum Number of COMMAND Elements True 
 +</​cli>​ 
 + 
 +=== The lg_term_dma attribute === 
 + 
 +For high throughput sequential I/O environments,​ use the start values lg_term_dma=0x400000 or 0x800000 (depending on the adapter type) and max_xfr_size=0x200000 
 + 
 +The AIX settings that can directly affect throughput performance with large I/O block size are 
 +the lg_term_dma and max_xfer_size parameters for the fcs device 
 + 
 +The lg_term_dma AIX Fibre Channel adapter attribute controls the direct memory access 
 +(DMA) memory resource that an adapter driver can use. The default value of lg_term_dma is 
 +0x200000, and the maximum value is 0x8000000. 
 +One change is to increase the value of lg_term_dma to 0x400000. If you still experience poor 
 +I/O performance after changing the value to 0x400000, you can increase the value of this 
 +attribute again. If you have a dual-port Fibre Channel adapter, the maximum value of the 
 +lg_term_dma attribute is divided between the two adapter ports. Therefore, never increase the 
 +value of the lg_term_dma attribute to the maximum value for a dual-port Fibre Channel 
 +adapter because this value causes the configuration of the second adapter port to fail. 
 + 
 +=== The max_xfer_size attribute === 
 + 
 +The max_xfer_size AIX Fibre Channel adapter attribute controls the maximum transfer size of 
 +the Fibre Channel adapter. Its default value is 100,000, and the maximum value is 1,​000,​000. 
 +You can increase this attribute to improve performance. 
 +Setting the max_xfer_size attribute affects the size of the memory area that is used for data 
 +transfer by the adapter. With the default value of max_xfer_size=0x100000,​ the area is 16 MB, 
 +and for other allowable values of the max_xfer_size attribute, the memory area is 128 MB. 
 + 
 +===== LPAR client ===== 
 + 
 +==== queue_depth ==== 
 + 
 +vSCSI adapters have a fixed queue depth of **512** command elements per adapter. 
 + 
 +Depending on the disk queue_depth,​ you can calculate the maximum LUN per adapter 
 +  Maximum disks per adapter = ( 512 – 2 ) / ( 3 + queue depth ) 
 +  
 +Ex: 
 +  A queue depth of 32 allows 510 / 35 = 14 LUNs per adapter. 
 +==== VIOS vs LPAR client ==== 
 + 
 +On which VIOS is connected a virtual FC adapter 
 +<cli prompt='#'>​ 
 +root@aix01 /​proc/​sys/​adapter/​fc/​fcs0 # cat hostinfo 
 +VFC client adapter name                   : fcs0 
 +Host partition name  (VIOS) ​              : vio2 
 +VFC host adapter name                     : vfchost2 
 +VFC host adapter location code            : U9009.22A.7891CA0-V3-C16 
 +FC adapter name on VIOS                   : fcs1 
 +FC adapter location code  on VIOS         : U78D3.001.WZS0AJN-P1-C8-T1 
 +</​cli>​ 
 + 
 +or use KDB 
 + 
 +**VSCSI** 
 +<cli prompt='#'>​ 
 +# echo cvai | kdb -script 
 +read vscsi_scsi_ptrs OK, ptr = 0xF10009D5B0129E98 
 +(0)> cvai 
 +Executing cvai command 
 +NAME       ​STATE ​   CMDS_ACTIVE ​ ACTIVE_QUEUE ​      ​HOST 
 +vscsi0 ​    ​0x000007 0x000000001A 0x0                vios2->​vhost3 
 +</​cli>​  
 + 
 +**VFCS** 
 +<cli prompt='#'>​ 
 +# echo vfcs | kdb -script 
 +read vscsi_scsi_ptrs OK, ptr = 0xF10009D5B0129E98 
 +(0)> vfcs 
 +Executing vfcs command 
 +NAME    ADDRESS ​           STATE  OPENED CH HOST_ADAP ​  ​PHYS ​  ​HOST 
 +fcs0    0xF1000B01C0084000 0x0010 0x0001 8  Secure ​     Secure Secure 
 +fcs1    0xF1000B01C0088000 0x0010 0x0001 0  vfchost0 ​          ​vios1 
 +</​cli>​  
 + 
 +To prevent collecting these info on VIOS 3.1.3 or later 
 +<cli prompt='​$'>​ 
 +$ chdev -dev viosnpiv0 -attr secure_va_info=yes 
 +viosnpiv0 changed 
 + 
 +$ virtadapinfo -list 
 +secure : yes 
 +</​cli>​ 
 + 
 +===== Test script ===== 
 + 
 +==== for disk ==== 
 + 
 +https://​ftp.software.ibm.com/​aix/​tools/​perftools/​perfpmr/​perf72/​ 
 + 
 +https://​www.ibm.com/​support/​pages/​stress-test-your-aix-or-linux-server-nstress 
 + 
 +<​code>​ 
 +cd /usr1 
 +for f in 0 1 2 3 4 5 6 7 8 9 
 +do 
 +echo "​Creating file: f${f}"​ 
 +dd if=/​dev/​zero of=f${f} bs=1m count=1024 >/​dev/​null 2>&​1 
 +done 
 + 
 +Run(){ 
 +ndisk64 -f f1 -C -r 100 -R -b 1m -t 20 -M 4 |grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f1 -C -R -b 1m -t 20 -M 4|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f1 -C -S -b 1m -t 20 -M 4|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f1 -C -R -r 0 -b 1m -t 20 -M 4|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f1 -C -S -r 0 -b 1m -t 20 -M 4|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f0,​f1,​f2,​f3,​f4,​f5,​f6,​f7,​f8,​f9 -C -r 100 -R -b 1m -t 20 -M 4|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f0,​f1,​f2,​f3,​f4,​f5,​f6,​f7,​f8,​f9 -C -r 100 -R -b 1m -t 20 -M 10|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f0,​f1,​f2,​f3,​f4,​f5,​f6,​f7,​f8,​f9 -C -r 100 -S -b 1m -t 20 -M 10|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f0,​f1,​f2,​f3,​f4,​f5,​f6,​f7,​f8,​f9 -C -S -b 1m -t 20 -M 10|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f0,​f1,​f2,​f3,​f4,​f5,​f6,​f7,​f8,​f9 -C -R -b 1m -t 20 -M 10|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f0,​f1,​f2,​f3,​f4,​f5,​f6,​f7,​f8,​f9 -C -R -r 0 -b 1m -t 20 -M 10|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +ndisk64 -f f0,​f1,​f2,​f3,​f4,​f5,​f6,​f7,​f8,​f9 -C -S -r 0 -b 1m -t 20 -M 10|grep TOTALS|awk '​{print $2,​$3,​$5}'​ 
 +
 +Run 
 +</​code>​ 
 + 
 +===== LPM between ​P7 and P8 =====
  
 **Only valid on P9 environment** **Only valid on P9 environment**
aix/aix_tuning_param.1637684385.txt.gz · Last modified: 2021/11/23 17:19 by manu