This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
storage:svc_esc_config [2024/11/07 23:59] manu |
storage:svc_esc_config [2025/03/17 17:17] (current) manu |
||
|---|---|---|---|
| Line 5: | Line 5: | ||
| Example of cabling | Example of cabling | ||
| - | In the best recommandations, alternate one port on Fabric SAN A, then a port on B... | + | In the best recommandations, alternate one port on Fabric SAN A (blue), then a port on B (red)... |
| + | |||
| + | {{:storage:svc_fc_connexions_08.png?4000}} | ||
| + | |||
| + | {{:storage:svc_fc_connexions_09.png?2000}} | ||
| - | {{:storage:SVC SA2-SV3 connection.png?650}} | ||
| Set the port mask to 11, so only ports 1 and 2 are able to communicate in node | Set the port mask to 11, so only ports 1 and 2 are able to communicate in node | ||
| <cli prompt='>'> | <cli prompt='>'> | ||
| - | SVC:superuser>chsystem -localfcportmask 00000011 | + | SVC:superuser>chsystem -localfcportmask 00001100 |
| SVC:superuser>lssystem |grep mask | SVC:superuser>lssystem |grep mask | ||
| - | local_fc_port_mask 0000000000000000000000000000000000000000000000000000000000000011 | + | local_fc_port_mask 00000000000000000000000000000000000000000000000000000000001100 |
| </cli> | </cli> | ||
| - | FIXME Why using 2 set of ports for host with different speed ? | + | FIXME Why using 2 set of ports for host with different speed flagged 16Gb and 32Gb?\\ |
| - | It's a best practice preventing SVC ports to negotiate between different speeds on hosts | + | It's a best practice preventing SVC ports to negotiate between different speeds on hosts. Dedicated ports for high speed traffic. But on SAN switches leave the auto-negotiation so both can do 32Gb. |
| {{:storage:SAN zoning for SVC enhanced stretch cluster.png?650}} | {{:storage:SAN zoning for SVC enhanced stretch cluster.png?650}} | ||
| Line 25: | Line 28: | ||
| https://www.ibm.com/support/pages/troubleshooting-svcstorwize-npiv-connectivity | https://www.ibm.com/support/pages/troubleshooting-svcstorwize-npiv-connectivity | ||
| + | |||
| ===== Storage connectivity ===== | ===== Storage connectivity ===== | ||
| - | Nowadays (2024), storage using NVMe are not supported, only SCSI over FC. Hosts are supported with NVMe over FC, SCSI over FC, ... network storage protocols | + | Nowadays (2024), <color #ed1c24>storage using NVMe are not supported</color>, only SCSI over FC. Hosts are supported with NVMe over FC, SCSI over FC, ... network storage protocols |
| For storage IBM change the layer at storage array to **storage** | For storage IBM change the layer at storage array to **storage** | ||
| Line 38: | Line 42: | ||
| * For node inter-connection use also pWWPN only. | * For node inter-connection use also pWWPN only. | ||
| * For hosts, use vWWPN with SCSI or NVMe protocols. | * For hosts, use vWWPN with SCSI or NVMe protocols. | ||
| + | |||
| + | On SAN switch, for each storage ports, increase the **buffercredit to 40** for 16Gb or 32Gb | ||
| + | <cli prompt='>'> | ||
| + | sansw01:admin> portcfgfportbuffers --enable 0 40 | ||
| + | </cli> | ||
| ===== Configuring Enhanced Stretch Cluster ===== | ===== Configuring Enhanced Stretch Cluster ===== | ||