storage:v7k_firmwaredisk [2022/01/15 10:10] manu |
storage:v7k_firmwaredisk [2024/09/10 17:12] (current) manu [ERRORS] |
||
|---|---|---|---|
| Line 22: | Line 22: | ||
| </cli> | </cli> | ||
| + | ==== For new versions ==== | ||
| + | <cli prompt='>'> | ||
| + | IBM_FlashSystem:f7krcs1:superuser>svcupgradetest -w IBM_FlashSystem7x00_and_StorwizeV7000_8.5.0.0_AND_LATER_ALL_DRIVES_230925 | ||
| + | rbash: svcupgradetest: command not found | ||
| + | |||
| + | IBM_FlashSystem:f7krcs1:superuser>svctask applysoftware -file IBM_INSTALL_FROM_8.5_AND_LATER_upgradetest_41.1 | ||
| + | CMMVC9001I The package installed successfully. | ||
| + | |||
| + | IBM_FlashSystem:f7krcs1:superuser>svcupgradetest -w IBM_FlashSystem7x00_and_StorwizeV7000_8.5.0.0_AND_LATER_ALL_DRIVES_230925 | ||
| + | svcupgradetest version 41.1 | ||
| + | |||
| + | Please wait, the test may take several minutes to complete. | ||
| + | |||
| + | Build version 231005_1440 | ||
| + | |||
| + | Results of running svcupgradetest: | ||
| + | ================================== | ||
| + | |||
| + | All drives have passed all the required pre-firmware upgrade checks. | ||
| + | Proceed with drive firmware upgrade shortly. | ||
| + | |||
| + | IBM_FlashSystem:f7krcs1:superuser>applydrivesoftware -file IBM_FlashSystem7x00_and_StorwizeV7000_8.5.0.0_AND_LATER_ALL_DRIVES_230925 -all | ||
| + | |||
| + | IBM_FlashSystem:f7krcs1:superuser>lsdriveupgradeprogress | ||
| + | id status estimated_completion_time | ||
| + | 0 upgrading 231011142128 | ||
| + | 1 scheduled | ||
| + | 2 scheduled | ||
| + | 3 scheduled | ||
| + | 4 scheduled | ||
| + | 5 scheduled | ||
| + | 6 scheduled | ||
| + | 7 scheduled | ||
| + | 8 scheduled | ||
| + | 9 scheduled | ||
| + | 10 scheduled | ||
| + | 11 scheduled | ||
| + | 12 scheduled | ||
| + | 13 scheduled | ||
| + | 14 scheduled | ||
| + | 15 scheduled | ||
| + | </cli> | ||
| === Check for firmware on V3700 === | === Check for firmware on V3700 === | ||
| Line 119: | Line 161: | ||
| Jobs are still pending during days when using command **lsdriveupgradeprogress** | Jobs are still pending during days when using command **lsdriveupgradeprogress** | ||
| - | Try to apply the firmware on a not existing disk | + | **<color #ed1c24>Try to apply the firmware on a not existing disk</color>** |
| <cli prompt='>'> | <cli prompt='>'> | ||
| IBM_Storwize:V7K:superuser >applydrivesoftware -drive 999 -file /home/admin/upgrade/IBM_FlashSystem7x00_and_StorwizeV7000_SAS_DRIVE_201027 -type firmware | IBM_Storwize:V7K:superuser >applydrivesoftware -drive 999 -file /home/admin/upgrade/IBM_FlashSystem7x00_and_StorwizeV7000_SAS_DRIVE_201027 -type firmware | ||