User Tools

Site Tools


hardware:megaraid

LSI MegaRAID controllers

StorCLI is the successor of the MegaCLI and allows Command Line Tools to manage and control LSI MegaRAID controllers.

You can download it by Broadcom

Add a disk to an existing RAID

Show all RAID controllers

# storcli show all

If the controller has the ID 0, then add /c0

# storcli /c0 show all

If an virtual disk for example RAID 5 exist, here v0, then you 'll see it

You can also see all attached physical disks on this adapter

Choose the disk in state UGOOD to add to the RAID

# storcli /c0/v0 start migrate type=raid5 option=add drive=134:5

Check the RAID expansion progress, indicate also the duration

# storcli /c0/v0 show migrate

Command line

Information for general use:

  /cx bzw. /vx stands for the Controller/Virtual Drive Number.
  /ex bzw. /sx stands for the Enclosure/Slot ID.

Additional information is also available in the LSI StorCLI manual.[1] Firmware Update

sudo storcli /cx download file=/path/to/firmware.rom

Information on the Controller and Configuration

sudo storcli /cx show all

Activation of Features (e.g. CacheCade, FastPath,…)

sudo storcli /cx set aso key=AAAAAAAABBBBBBBBCCCCCCCC

Information on the existing hard drives and their status (IDs,…)

sudo storcli /cx /eall /sall show (all)

Information on the existing virtual drives and their status

sudo storcli /cx /vall show (all)

View current status of all rebuilds

sudo storcli /cx /eall /sall show rebuild

Creating a Virtual Drive

sudo storcli /cx add vd type=[RAID0(r0)|RAID1(r1)|…] drives=[EnclosureID:SlotID|:SlotID-SlotID|:SlotID,SlotID]

Example:

sudo storcli /cx add vd type=r1 drives=252:0-2

Initializing a VD

sudo storcli /cx/vx start init (force)

Progress can be monitored using the following command:

sudo storcli /cx/vx show init

Creating a CacheCade device

sudo storcli /cx add vd cc type=r[0,1,10] drives=[EnclosureID:SlotID|:SlotID-SlotID|:SlotID,SlotID] WT|WB (assignvds=0,1,2)

Example:

sudo storcli /c0 add vd cc type=r1 drives=252:2-3 WB

CacheCade activation/deactivation

sudo storcli /cx/[vx|vall] set ssdCaching=[on|off]

Example:

sudo storcli /c0/v1 set ssdCaching=on

Removing a CacheCade device

sudo storcli /cx/vx del cc

Removing a VD

sudo storcli /cx/vx del (force)

Incorporating an improperly removed device

If an improperly removed device is reconnected to the RAID controller it will be recognized as UBAD (Unconfigured Bad).

sudo storcli /c0 /eall /sall show

Controller = 0 Status = Success Description = Show Drive Information Succeeded.

Drive Information :


EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp


252:0 7 Onln 0 465.25 GB SATA HDD N N 512B WDC WD5003ABYX-01WERA1 U 252:1 6 Onln 1 465.25 GB SATA HDD N N 512B WDC WD5003ABYX-01WERA1 U 252:2 5 UGood - 465.25 GB SATA HDD N N 512B WDC WD5003ABYX-01WERA1 U 252:3 4 UBad - 223.062 GB SATA SSD N N 512B INTEL SSDSC2CW240A3 U


EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign UGUnsp-Unsupported

This status must be changed to UGOOD.

sudo storcli /cx /ex /sx set good

Controller = 0 Status = Success Description = Show Drive Information Succeeded.

Drive Information :


EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp


252:0 7 Onln 0 465.25 GB SATA HDD N N 512B WDC WD5003ABYX-01WERA1 U 252:1 6 Onln 1 465.25 GB SATA HDD N N 512B WDC WD5003ABYX-01WERA1 U 252:2 5 UGood - 465.25 GB SATA HDD N N 512B WDC WD5003ABYX-01WERA1 U 252:3 4 UGood F 223.062 GB SATA SSD N N 512B INTEL SSDSC2CW240A3 U


EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign UGUnsp-Unsupported

Now the device is foreign in the pool

sudo storcli /cx /fall show

Controller = 0 Status = Success Description = Operation on foreign configuration Succeeded

FOREIGN CONFIGURATION :


DG EID:Slot Type State Size NoVDs


0 - Cac0 Frgn 223.062 GB 1


NoVDs - Number of VDs in disk group|DG - Diskgroup Total foreign drive groups = 1

Now it can be included in the configuration.

sudo storcli /cx /fall import

If the device was part of a RAID a rebuild is performed automatically (see the state: Rbld in the overview). The following command progress can be monitored:

sudo storcli /cx /ex /sx show rebuild

hardware/megaraid.txt · Last modified: 2025/03/23 21:06 by manu