User Tools

Site Tools


storage:svc_esc_config

This is an old revision of the document!


SVC Enhanced Stretch Cluster configuration

SVC cabling and zoning

Example of cabling

In the best recommandations, alternate one port on Fabric SAN A, then a port on B…

Set the port mask to 11, so only ports 1 and 2 are able to communicate in node

SVC:superuser>chsystem -localfcportmask 00000011 

SVC:superuser>lssystem |grep mask
local_fc_port_mask 0000000000000000000000000000000000000000000000000000000000000011

SVC port connexion to SAN SW

https://www.ibm.com/support/pages/troubleshooting-svcstorwize-npiv-connectivity

Storage connectivity

Nowadays (2024), storage using NVMe are not supported, only SCSI over FC. Hosts are supported with NVMe over FC, SCSI over FC, … network storage protocols

For storage IBM change the layer at storage array to storage

  • Zone the FC SCSI NPIV (vWWPN) port from storage to SVC physical port (pWWPN)
  • For node inter-connection use also pWWPN only.
  • For hosts, use vWWPN with SCSI or NVMe protocols.

Configuring Enhanced Stretch Cluster

Before configuring all nodes, wait:

  • Configure the first node as a cluster node
  • Start the other nodes
  • Do the private zoning
  • All other nodes started 'll be candidates (if they are still configured, go to the GUI and do a remove node)
  • Add the candidates nodes to the cluster
  • configure ALL service IP (on each node)
  • Download and install the IP quorum
  • Create the zoning for the external storage (controllers)

Now you are ready to configure the Enhanced Stretch Cluster

storage/svc_esc_config.1731019641.txt.gz · Last modified: 2024/11/07 23:47 by manu